TeSys AUXILIARY CONTACTOR Schneider

Schneider Electric CAD50BL TeSys Auxiliary Contactor (Control Relay)

The Schneider Electric CAD50BL is a TeSys Deca (TeSys D) control relay / auxiliary contactor designed for control and interface circuits. It features 5 Normally Open (5NO) contacts, a 24 VDC low-consumption coil, and is suitable for switching electromagnetic loads in AC-15, AC-14, and DC-13 control applications. The device is DIN-rail or panel mounted and is widely used in industrial automation, motor control, signaling, and interlocking circuits.

Key Features

  • 5 NO auxiliary/control contacts
  • 24 VDC low-consumption electronic coil
  • Built-in surge suppression
  • Compact 45 mm wide design
  • DIN rail or panel mounting
  • Suitable for high switching frequency applications (up to 180 operations/minute)
  • Long mechanical life of 30 million operations
  • Industrial certifications for worldwide use
  • Designed for AC-14, AC-15, and DC-13 control duties.

Specifications

Manufacturer Schneider Electric
Product Series TeSys Deca / TeSys D
Product Name TeSys CAD
Model / Part Number CAD50BL
Product Type Control Relay / Auxiliary Contactor
Device Short Name CAD
Application Control circuits, automation, signaling, interlocking
Contact Configuration 5 NO (5 Normally Open)
Utilization Category AC-14, AC-15, DC-13
Rated Operational Voltage (Ue) Up to 690 V AC, 25...400 Hz
Control Circuit Type DC Low Consumption Coil
Coil Voltage (Uc) 24 V DC
Surge Suppression Integrated suppression device
Conventional Thermal Current (Ith) 10 A at 60°C
Rated Impulse Withstand Voltage (Uimp) 6 kV
Rated Insulation Voltage (Ui) 690 V IEC; 600 V UL/CSA
Rated Making Capacity (Irms) 140 A AC, 250 A DC
Rated Short-Time Withstand Current (Icw) 100 A (1 s), 120 A (500 ms), 140 A (100 ms)
Recommended Fuse 10 A gG
Inrush Power Consumption 2.4 W at 20°C
Holding Power Consumption 2.4 W at 20°C
Maximum Operating Rate 180 cycles/min
Mechanical Durability 30 million operations
Time Constant 40 ms
Coil Energization Time 65...88 ms
Coil De-Energization Time 14...25 ms
Minimum Switching Voltage 17 V
Minimum Switching Current 5 mA
Insulation Resistance 10 MΩ
Non-Overlap Time 1.5 ms
Mounting DIN Rail (35 mm) or Panel/Plate Mount
Terminal Type Screw Clamp Terminals
Width 45 mm
Height 77 mm
Depth 93 mm
Weight 0.58 kg
Protection Degree IP2X
Ambient Temperature Range -40°C to +60°C (operation), up to +70°C under specified conditions
Shock Resistance 10 Gn open, 15 Gn closed (11 ms)
Vibration Resistance 2 Gn open, 4 Gn closed, 5...300 Hz
Protective Treatment TH
Recyclability 75%
Certifications IEC, UL, CSA, CCC, EAC, CE, UKCA, CB, Marine
Compliance Standards IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, GB/T 14048.5, JIS C8201-5-1
Connection Capacity (Flexible Wire) 1× 1...4 mm² or 2× 1...4 mm²
Connection Capacity (Flexible with Ferrule) 1× 1...4 mm² or 2× 1...2.5 mm²
Connection Capacity (Solid Wire) 1× 1...4 mm² or 2× 1...4 mm²
Tightening Torque 1.7 N·m
More in Switch