TeSys AUXILIARY N/O N/C TOP Schneider

Schneider Electric GVAE11 – TeSys AUXILIARY N/O N/C TOP

The GVAE11 is a TeSys GV auxiliary contact block designed for use with Schneider Electric GV2 and GV3 motor circuit breakers/manual motor starters. It provides one normally open (1 NO) and one normally closed (1 NC) instantaneous auxiliary contact for signaling, status indication, interlocking, and control circuit applications. The unit mounts directly on the top/front side of compatible motor protection breakers and features screw-clamp terminal connections.

Key Features

  • Compatible Devices
  • GV2ME Motor Circuit Breakers
  • GV2P Motor Circuit Breakers
  • GV2L Manual Motor Switches
  • GV2LE Motor Protection Switches
  • GV2RT Motor Protection Devices
  • GV2LM Series Devices
  • GV3P Motor Circuit Breakers

Specifications

Manufacturer Schneider Electric
Model Number GVAE11
Commercial Description TeSys AUXILIARY N/O N/C TOP
Product Range TeSys Deca
Device Short Name GVAE
Product Type Auxiliary Contact Block
Function Instantaneous Auxiliary Contacts
Contact Configuration 1 NO + 1 NC
Number of Contacts 2
Contact Type Instantaneous
Mounting Location Front Side / Top Mount
Mounting Style Front Mount
Compatible Product Family GV2 and GV3 Motor Circuit Breakers
Product Compatibility GV2ME, GV2P, GV2L, GV2LE, GV2RT, GV2LM, GV3P, GV3L
Connection Method Screw Clamp Terminals
Terminal Type Screw Terminal
Application Signaling, Interlocking, Status Indication, Auxiliary Control Circuits
Quantity per Set Set of 10 (Industrial Packaging)
Rated Operational Voltage (Ue) AC 24 to 240 VAC
Rated Operational Voltage (Ue) DC 24 to 60 VDC
Rated Insulation Voltage (Ui) IEC 250 V
Rated Insulation Voltage (Ui) UL 508 300 V
Rated Insulation Voltage (Ui) CSA 300 V
Conventional Free-Air Thermal Current (Ith) 2.5 A
Maximum AC Contact Rating 2 A at 240 VAC
Maximum DC Contact Rating 1 A at 60 VDC
Minimum Switching Voltage 17 V
Minimum Switching Current 5 mA
Rated Impulse Withstand Voltage Not specified by manufacturer
Contact Operation Instantaneous
Voltage / Duty Rated Power
24 VAC AC-15 48 VA
48 VAC AC-15 60 VA
110-120 VAC AC-15 120 VA
230-240 VAC AC-15 120 VA
DC-13 (24 VDC) 15 W
DC-13 (48 VDC) 15 W
DC-13 (60 VDC) 15 W
Recommended Fuse Protection gG Fuse 10 A
Circuit Breaker Protection GB2CB06, 10 A
Contact Protection Type Auxiliary Control Circuit Protection
Insulation Class Industrial Control Grade
Mechanical Durability 100,000 Cycles
Electrical Durability 100,000 Cycles (AC-15 Ratings)
Operating Mode Instantaneous
Mounting Position Front Mounted
Weight Approx. 0.02 kg
Width 45 mm
Height 11 mm
Depth 29 mm
Solid Conductors (1 Cable) 1 to 2.5 mm²
Solid Conductors (2 Cables) 1 to 2.5 mm²
Flexible Conductors Without Ferrule (1 Cable) 0.75 to 2.5 mm²
Flexible Conductors Without Ferrule (2 Cables) 0.75 to 2.5 mm²
Flexible Conductors With Ferrule (1 Cable) 0.75 to 1.5 mm²
Terminal Connection Screw Clamp
Recyclability Potential 42%
Carbon Footprint 0.2 kg CO₂ eq.
RoHS Compliance Yes
REACH Compliance Yes
Green Premium Product Yes
Standard / Approval Status
IEC 60947-1 Compliant
UL 508 Certified
CSA C22.2 No.14 Certified
IEC Certified
UL Listed
CSA Approved
CCC Certified
EAC Certified
CE Marking Yes
RoHS Compliant
REACh Compliant
Auxiliary Signaling Provides breaker status feedback
Contact Arrangement 1 Normally Open + 1 Normally Closed
Top/Front Mounting Direct installation on GV2/GV3 breakers
Instantaneous Operation No intentional delay
Compact Design Minimal panel space required
Industrial Reliability 100,000 mechanical operations
Wide Voltage Range 24-240 VAC, 24-60 VDC
Easy Wiring Screw clamp terminals
Global Approvals IEC, UL, CSA, CCC, EAC
More in Switch

Related Products

A9N26899

Acti9 A9N OF+SD 24 VDC Ti24 term on top - Schneider

View Details

A9N2P02CGN

Acti9 xC60 2P C 2A MCB IS/IEC 60898-1-Schneider

View Details

A9N2P04CGN

Acti9 xC60 2P C 4A MCB IS/IEC 60898-1-Schneider

View Details
Need More Information?

Talk to our team about GVAE11.