TeSys AUXILIARY N/O N/C TOP Schneider
The GVAE11 is a TeSys GV auxiliary contact block designed for use with Schneider Electric GV2 and GV3 motor circuit breakers/manual motor starters. It provides one normally open (1 NO) and one normally closed (1 NC) instantaneous auxiliary contact for signaling, status indication, interlocking, and control circuit applications. The unit mounts directly on the top/front side of compatible motor protection breakers and features screw-clamp terminal connections.
| Manufacturer | Schneider Electric |
|---|---|
| Model Number | GVAE11 |
| Commercial Description | TeSys AUXILIARY N/O N/C TOP |
| Product Range | TeSys Deca |
| Device Short Name | GVAE |
| Product Type | Auxiliary Contact Block |
| Function | Instantaneous Auxiliary Contacts |
| Contact Configuration | 1 NO + 1 NC |
| Number of Contacts | 2 |
| Contact Type | Instantaneous |
| Mounting Location | Front Side / Top Mount |
| Mounting Style | Front Mount |
| Compatible Product Family | GV2 and GV3 Motor Circuit Breakers |
| Product Compatibility | GV2ME, GV2P, GV2L, GV2LE, GV2RT, GV2LM, GV3P, GV3L |
| Connection Method | Screw Clamp Terminals |
| Terminal Type | Screw Terminal |
| Application | Signaling, Interlocking, Status Indication, Auxiliary Control Circuits |
| Quantity per Set | Set of 10 (Industrial Packaging) |
| Rated Operational Voltage (Ue) AC | 24 to 240 VAC |
| Rated Operational Voltage (Ue) DC | 24 to 60 VDC |
| Rated Insulation Voltage (Ui) IEC | 250 V |
| Rated Insulation Voltage (Ui) UL 508 | 300 V |
| Rated Insulation Voltage (Ui) CSA | 300 V |
| Conventional Free-Air Thermal Current (Ith) | 2.5 A |
| Maximum AC Contact Rating | 2 A at 240 VAC |
| Maximum DC Contact Rating | 1 A at 60 VDC |
| Minimum Switching Voltage | 17 V |
| Minimum Switching Current | 5 mA |
| Rated Impulse Withstand Voltage | Not specified by manufacturer |
| Contact Operation | Instantaneous |
| Voltage / Duty | Rated Power |
| 24 VAC AC-15 | 48 VA |
| 48 VAC AC-15 | 60 VA |
| 110-120 VAC AC-15 | 120 VA |
| 230-240 VAC AC-15 | 120 VA |
| DC-13 (24 VDC) | 15 W |
| DC-13 (48 VDC) | 15 W |
| DC-13 (60 VDC) | 15 W |
| Recommended Fuse Protection | gG Fuse 10 A |
| Circuit Breaker Protection | GB2CB06, 10 A |
| Contact Protection Type | Auxiliary Control Circuit Protection |
| Insulation Class | Industrial Control Grade |
| Mechanical Durability | 100,000 Cycles |
| Electrical Durability | 100,000 Cycles (AC-15 Ratings) |
| Operating Mode | Instantaneous |
| Mounting Position | Front Mounted |
| Weight | Approx. 0.02 kg |
| Width | 45 mm |
| Height | 11 mm |
| Depth | 29 mm |
| Solid Conductors (1 Cable) | 1 to 2.5 mm² |
| Solid Conductors (2 Cables) | 1 to 2.5 mm² |
| Flexible Conductors Without Ferrule (1 Cable) | 0.75 to 2.5 mm² |
| Flexible Conductors Without Ferrule (2 Cables) | 0.75 to 2.5 mm² |
| Flexible Conductors With Ferrule (1 Cable) | 0.75 to 1.5 mm² |
| Terminal Connection | Screw Clamp |
| Recyclability Potential | 42% |
| Carbon Footprint | 0.2 kg CO₂ eq. |
| RoHS Compliance | Yes |
| REACH Compliance | Yes |
| Green Premium Product | Yes |
| Standard / Approval | Status |
| IEC 60947-1 | Compliant |
| UL 508 | Certified |
| CSA C22.2 No.14 | Certified |
| IEC | Certified |
| UL | Listed |
| CSA | Approved |
| CCC | Certified |
| EAC | Certified |
| CE Marking | Yes |
| RoHS | Compliant |
| REACh | Compliant |
| Auxiliary Signaling | Provides breaker status feedback |
| Contact Arrangement | 1 Normally Open + 1 Normally Closed |
| Top/Front Mounting | Direct installation on GV2/GV3 breakers |
| Instantaneous Operation | No intentional delay |
| Compact Design | Minimal panel space required |
| Industrial Reliability | 100,000 mechanical operations |
| Wide Voltage Range | 24-240 VAC, 24-60 VDC |
| Easy Wiring | Screw clamp terminals |
| Global Approvals | IEC, UL, CSA, CCC, EAC |